SEWAGE TREATMENT

HOTEL WASTEWATER TREATMENT

OVERVIEW

You can treat your Hotel Wastewater Treatment with our Tricel Maxus wastewater treatment.

From dense urban areas to secluded country destinations, accommodation is becoming readily available in various types, shapes, and sizes to suit every traveller’s preferences and needs. 

An efficient and well-functioning wastewater treatment system is crucial for ensuring guests’ satisfaction, safeguarding the ecosystem, and meeting legal and regulatory requirements.

+35 364 6655615

If you have any questions, feel free to call us

Share on Facebook
Share on LinkedIn

VISIT OUR virtual SHOWROOM

​REPAIRING OR UPGRADING AN EXISTING SYSTEM?

High-quality water is essential for your customers, while a reliable wastewater treatment system is vital for the health of the ecosystem. If you’re experiencing issues with your current system, such as a septic tank, it’s time to address and fix them.

The first thing you should do is ensure that the natural water sources around your hotel property are safe. There should be no concern about wastewater contamination in a well-maintained septic system. In the absence of clean water, public health and safety are put at risk. You must fix your septic tank immediately to avoid legal repercussions and fees. Long-term solutions involve investing in modern wastewater treatment systems instead of repairing old ones

Whether upgrading or constructing a new wastewater treatment system, Tricel Maxus is your solution.

HOTEL WASTEWATER TREATMENT REQUIREMENTS

Tricel provides hotel wastewater treatment plants explicitly designed to meet the needs of the industry.

A hotel’s wastewater treatment system should accommodate highly variable wastewater flows and loadings during events such as conferences and weddings. The demand fluctuates considerably from season to season. Overloading at peak times will increase BOD, Ammonia and suspended solids, which can cause compliance issues. We manage this in our wastewater treatment plants by controlling and equalizing the peak flows.

With on-site catering, elevated levels of fats, oils, and grease (FOG) affects hotel wastewater. High FOG levels can also fail to meet the ammonia limit values in the final effluent to increase COD. Therefore, any design of a treatment plant must include kitchen wastewater. Additionally, you need an add-on solution to remove fats, oils, grease, ammonia, and COD from hotel wastewater.

The Tricel wastewater treatment plant is a submerged aeration plant. This plant uses a simple proven technology which treats the wastewater with natural micro organisms sustained in the plant with air giving superior treatment results. Learn more about Wastewater Treatment System Do’s and Dont’s.

Hotel Wastewater Treatment Solution

Tricel offers several wastewater treatment solutions that can be adapted to any type of project, such as the Tricel Maxus Wastewater treatment, designed to treat wastewater from small communities and commercial properties greater than 50 PE. Multiple configurations that fit any site are robust, easy to install, and simple to operate; they are easy to maintain over the product’s lifespan. Hotel sewage can be treated and disposed of using our Tricel Maxus commercial wastewater treatment systems.

There are many factors to consider before choosing the best wastewater treatment system for your hotel. Hotel size, number of wastewater generating units, daily wastewater volumes, and peak and off-season volumes. You must install an efficient system to conserve resources and protect the environment. 

The wastewater treatment Tricel Maxus guarantee full compliance with the EPA‘s licence conditions. No matter the size restrictions or limitations, we can provide multiple configurations that suit your needs. Highly efficient sewage treatment plants substantially reduce hotel and guest house operational and maintenance costs.

Tricel’s advantages for Hotel Wastewater Treatment

Wastewater treatment is suitable for more than 50 Population Equivalent (PE) applications.

  • Hotels rely on our Tricel Maxus Commercial Plant for permanent and seasonal operations. The control panel will automatically adjust to the incoming load to ensure optimal performance. When no flow is detected, the system goes into power-saving mode and restarts as soon as the flow is detected.
  • We provide bespoke wastewater treatment solutions regardless of the available space, above ground or below ground, or the effluent standard. If a breach of a discharge licence or permit causes a compliance issue with the environment agency, we can upgrade to ensure full compliance.
  • With the latest developments in commercial wastewater treatment, Tricel provides low-cost, reliable hotel wastewater treatment using low energy. Low running costs result from simple operation using long-life, reliable components. Easy maintenance is made possible by the lack of moving parts within the plant.

50 years in business

A highly successful multinational corporation with over 50 years’ valuable industry experience

SEWAGE TREATMENT PLANTS

Plants available for all capacities, from 1PE up to 50PE. Free advice on request.

Fast Delivery

On-time delivery is a core requirement of our successful business operations

Meet our team

To find a technician in your area, visit our page

TALK SEWAGE TREATMENT

To speak to one of our agents online, click here

ASK FOR A QUOTE

Request a free quote today to have a quote that meets your project!

Our range of products

Tricel Vento Septic Tank

Shallow dig tank, strong & robust underground tank, No electrical or moving parts. Ideal for sites with good drainage & plenty of space.

Learn more

Tricel Novo Sewage Treatment Plant

Durable & long lasting SMC tank, shallow dig tank, easy installation (Plug and Play), long life components.

Learn more

Tricel Maxus Sewage Treatment Plant

Commercial plant. Submerged Aerated Filter (SAF) technology. Ideal for every project over 50 Population Equivalent.

Learn more

Tricel Tero Tertiary Treatment

An eco-friendly and modular system with proven E.Coli Treatment capabilities in line with the new EPA requirements.

Learn more

Tricel Puraflo Secondary treatment plant

Ideal for sensitive sites, compliant to Irish Standard, small footprint.

Learn more

Tricel Sandcel
Sand Polishing Filter

Provides a dual function of polishing the effluent from a wastewater treatment system and disposing it into groundwater.

Learn more

Tricel Pumping Stations

Pump fluids from one place to another where gravity drainage cannot be used, easy and trouble-free installation

Learn more

Key features

Cost-Effective

Operating costs are reduced to

a minimum

quality

Sewage treatment plants are extremely reliable and durable as they are made out of long-lasting materials (20 to 40 years)

Certified

All Tricel Novo sewage treatment plants are tested to the highest quality standards and are EU Certified to EN12566-3

Frequently Asked Questions

PE represents the initials of Population Equivalent. Population equivalent: conversion value which aims at expressing non-domestic applications in terms of domestic loading based on 1 person creates 60 g/day BOD5 and 150l/day. (Code of Practice: Wastewater Treatment and Disposal Systems Serving Single Houses (p.e. < 10), EPA)

Tricel Novo Vitae

 Both are wastewater treament plant solutions manufactured by Tricel. Wastewater treatment plants offer a superior quality of treatment. For example, the Tricel Novo comprises of three independent wastewater treatment zones and offers an average of efficiency of 95.9% BOD removal.
This is a higher treatment standard than the effluent from a septic tank. Please note: all wastewater treatment plants used in Ireland must comply with the EN12566-3 standard and all septic tanks must comply with the EN12566-1 standard..

Tricel Vento

The septic tank from Tricel is manufactured as a primary treatment. Designed for the settlement of your effluent. This product may need an additional treatment like the Sandcel or Puraflo.

Most Tricel products have a warranty. To discover all the guarantees on our products, as well as on the internal parts, consult our dedicated product pages.

The required standards are 20:30:20 BOD, SS, NH4. All Tricel produces exceed the requirements when tested to En12566-3 and comply with SR66.

Learn more about our certification

Tricel recommends that you maintain your device to the fullest. You are obliged by law to avoid all types of pollution or nuisances. Do not hesitate to contact us for more information on our service contracts. An annual maintenance contract may be offered.

Get in touch